- Arts & Culture 6213
- Business & Economics 674
- Computers 316
- Dictionaries & Encyclopedias 74
- Education & Science 76877
- Abstracts 73
- Astrology 4
- Biology 8
- Chemistry 4046
- Coursework 15549
- Culture 8
- Diplomas 316
- Drawings 1595
- Ecology 5
- Economy 76
- English 80
- Ethics, Aesthetics 3
- For Education Students 17573
- Foreign Languages 11
- Geography 3
- Geology 1
- History 88
- Maps & Atlases 5
- Mathematics 12624
- Musical Literature 2
- Pedagogics 19
- Philosophy 22
- Physics 15120
- Political Science 5
- Practical Work 59
- Psychology 63
- Religion 4
- Russian and culture of speech 8
- School Textbooks 7
- Sociology 9
- Summaries, Cribs 87
- Test Answers 160
- Tests 8747
- Textbooks for Colleges and Universities 32
- Theses 7
- To Help Graduate Students 14
- To Help the Entrant 38
- Vetting 385
- Works 13
- Информатика 8
- Engineering 893
- Fiction 706
- House, Family & Entertainment 84
- Law 129
- Website Promotion 68
112. Solving a chemistry problem
Refunds: 0
Uploaded: 16.08.2022
Content: 19в.rar 22,11 kB
Product description
19th century To separate copper(II) from iron(III) with subsequent titrimetric determination of copper(II), a strongly acid KU-2 cation exchanger in the H-form was used.
Sulphosalicylic acid and ammonia were added to the analyzed solution (H3L) containing copper(II) and iron(III) cations. In this case, the copper(II) cation passed into the cationic complex [Cu(NH3)4]2 sorbed by the cation exchanger, and the iron(III) cation into the anionic complex [FeCl3]6- , not sorbed by the cation exchanger. The resulting solution was passed through a chromatographic column with an H-form cation exchanger and, to completely remove the iron complex, the column was washed with a mixture of solutions of sulfosalicylic acid and ammonia, and then with water, after which the copper complex with the cation exchanger was eluted with a solution of hydrochloric acid, the column was washed with water and collected in a volumetric flask with a capacity of Vk(Cu), the elluate containing the Cu2 cation was diluted with water up to the mark.
Determination of copper(II) in the resulting solution was carried out by indirect iodometric titration. At the same time, V(Na2S2O3) of sodium thiosulfate with a molar concentration of the equivalent c(Na2S2O3) was used to titrate an aliquot of the solution with a volume of Va(Cu) ml.
Write the equations for the reactions that occur on the cation exchanger (R-H) when a solution containing copper(II) and iron(III) complexes is passed through it and when the copper complex is eluted from the cation exchanger. Using the data below, calculate the mass of copper in the analyzed solution. (II)
Option in
Vk(Cu), ml 100
Va(Cu), ml 25.00
c(Na2S2O3), mol/l 0.03525
V(Na2S2O3), ml 7.35
Additional information
If you do not open the file - install the RAR archiver. Inside the archive you will find a solution in Word format.
Feedback
0Period | |||
1 month | 3 months | 12 months | |
0 | 0 | 0 | |
0 | 0 | 0 |