University: TUSUR
Year: 2009
The task of the course project:
It is necessary to develop a mechanical stress meter.
When developing it is necessary to consider the following:
1) primary transducer - a strain gauge glued to the structure when working under a load of 100 kg, changes its resistance by 10% of the nominal value of 180 Ohms in the direction of increase;
2) the average value of the sensor current should not exceed 5 * 10 ^ 3 A;
3) provide pulse power to the sensor included in the bridge circuit;
4) provide a digital readout of the load with an accuracy of 1 kg;
5) the temperature mode of the device is 20 degrees;
6) provide for the possibility of manually fixing the result for 2 minutes.
It is necessary to select and calculate the elements of the meter circuit. The selected elements should not only provide the required operation algorithm, but also provide the specified measurement accuracy.
Scope of work:
- Explanatory Note, pages: 37, MS Word
- Drawing of the electrical circuit diagram: A2, Compass-10
- The list of elements to the electrical circuit diagram: 3 sheets A4, Compass-10
Year: 2009
The task of the course project:
It is necessary to develop a mechanical stress meter.
When developing it is necessary to consider the following:
1) primary transducer - a strain gauge glued to the structure when working under a load of 100 kg, changes its resistance by 10% of the nominal value of 180 Ohms in the direction of increase;
2) the average value of the sensor current should not exceed 5 * 10 ^ 3 A;
3) provide pulse power to the sensor included in the bridge circuit;
4) provide a digital readout of the load with an accuracy of 1 kg;
5) the temperature mode of the device is 20 degrees;
6) provide for the possibility of manually fixing the result for 2 minutes.
It is necessary to select and calculate the elements of the meter circuit. The selected elements should not only provide the required operation algorithm, but also provide the specified measurement accuracy.
Scope of work:
- Explanatory Note, pages: 37, MS Word
- Drawing of the electrical circuit diagram: A2, Compass-10
- The list of elements to the electrical circuit diagram: 3 sheets A4, Compass-10
Main features
- Content type File
- Content description 400,21 kB
- Added to the site 11.08.2010
Additional description
The explanatory note is made in Word format, the formulas are typed in the Equation formula editor, the graphs are built in MathCad. Drawings and technical documentation are made in Compass-10.
Reviews
No reviews yet
The sale of this product is suspended.
teh-diplom
Blocked
teh-diplom
Blocked